CM&R HMORN 2009 Proceedings are now online!
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
 QUICK SEARCH:   [advanced]


     


First published online February 26, 2009
Clinical Medicine & Research; doi:10.3121/cmr.2009.819
© 2009 Marshfield Clinic
This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
cmr.2009.819v1
7/1-2/21    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Brodovicz, K. G.
Right arrow Articles by Yale, S. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Brodovicz, K. G.
Right arrow Articles by Yale, S. H.

Original Research

Reliability and Feasibility of Methods to Quantitatively Assess Peripheral Edema

Kimberly G. Brodovicz, DrPH

Department of Epidemiology, Merck Research Laboratories, North Wales, Pennsylvania

Kristin McNaughton, MHS

Department of Epidemiology, Merck Research Laboratories, North Wales, Pennsylvania

Naoto Uemura, MD

Department of Clinical Research–Clinical Pharmacology, Merck Research Laboratories, Rahway, New Jersey

Gary Meininger, MD

Department of Clinical Research–Metabolism, Merck Research Laboratories, Rahway, New Jersey

Cynthia J. Girman, DrPH

Department of Epidemiology, Merck Research Laboratories, North Wales, Pennsylvania

Steven H. Yale, MD

Department of Internal Medicine, Marshfield Clinic and Clinical Research Center, Marshfield Clinic Research Foundation, Marshfield, Wisconsin

Reprint Requests: Kimberly G. Brodovicz, DrPH, Department of Epidemiology, Merck Research Laboratories, PO Box 1000, UG1D-60, North Wales, PA 19454, Tel: 267-305-7490 Fax: 215-616-2042 Email:kimberly_brodovicz{at}merck.com

Abstract

Objective: To evaluate methods to assess peripheral edema for reliability, feasibility and correlation with the classic clinical assessment of pitting edema.

Design: Cross-sectional observational study.

Setting: Large primary care clinic in Marshfield, Wisconsin, USA.

Participants: Convenience sample of 20 patients with type 2 diabetes and a range of edema severity, including patients without edema.

Methods: Eight methods of edema assessment were evaluated: (1) clinical assessment of pit depth and recovery at three locations, (2) patient questionnaire, (3) ankle circumference, (4) figure-of-eight (ankle circumference using eight ankle/foot landmarks), (5) edema tester (plastic card with holes of varying size pressed to the ankle with a blood pressure cuff), (6) modified edema tester (edema tester with bumps), (7) indirect leg volume (by series of ankle/leg circumferences), and (8) foot/ankle volumetry by water displacement. Patients were evaluated independently by three nurse examiners.

Results: Water displacement and ankle circumference had high inter-examiner agreement (intraclass correlation coefficient 0.93, 0.96 right; 0.97, 0.97, left). Agreement was inconsistent for figure-of-eight (0.64, 0.86), moderate for indirect leg volume (0.53, 0.66), and low for clinical assessments at all locations. Agreement was low for the edema testers but varied by the pressure administered. Correlation with the classic, subjective clinical assessment was good for the nurse-performed assessments and patient questionnaire. Ankle circumference and patient questionnaires each took 1 minute to complete. Other tools took >5 minutes to complete.

Conclusions: Water displacement and ankle circumference showed excellent reliability; however, water displacement is a time-consuming measure and may pose implementation challenges in the clinical and clinical trial environments. Patient-reported level and frequency of edema, based on an unvalidated questionnaire, was generally well correlated with the physician assessment of edema severity and may prove to be another reliable and accurate method of assessing edema. Additional study is needed to evaluate the validity and responsiveness of these methods.


Key Words: Measurement • Peripheral edema • Reliability







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
Copyright © 2009 by Marshfield Clinic.